
2022 Valid 500-920 Real Exam Questions (Updated) 100% Dumps & Practice Exam
[UPDATED 2022] Cisco 500-920 Questions Prepare with Free Demo of PDF
NEW QUESTION 22
What three options should be verified, when you are able to connect to Cisco UCS Manager, but unable to open a KVM session to a blade? (Choose three)
- A. Verify the KVM IP Address is on the same subnet as the Fabric Interconnect management address
- B. Confirm the KVM IP Address is added to the route table in Cisco UCS Manager
- C. Verify TCP port 2068 is not blocked by an ACL or Firewall
- D. Confirm the IP Address assigned to UCS Manager is the same as the KVM address
- E. Verify the KVM IP Address is on the same ip subnet as the virtual machines
- F. Confirm the IP Address assigned to the KVM is not a duplicate IP
Answer: B,C,F
NEW QUESTION 23
Which two statements describes connecting the IO Modules in the UCS chassis to the Fabric interconnects? (Choose two )
- A. Connect Fl-B to the IOM B of each chassis
- B. Connect Fl-A to IOM A and IOM B in each chassis
- C. Connect Fl-B to the IOM A of each chassis
- D. Connect Fl-A to the IOM A of each chassis
- E. Connect Fl-B to IOM A and IOM B in each chassis
- F. Connect Fl-A to the IOM B of each chassis
Answer: A,D,F
NEW QUESTION 24
What is the likely cause of an intermittent SAN Boot fails?
- A. Misconfigured SAN boot target in the boot policy of the service profile
- B. LUN ID Mismatch
- C. Wrong boot order in the service profile
- D. FCoE used instead of FC
Answer: A
NEW QUESTION 25
Which Cisco UCS internal component maintains the UCS XML database, manages the FSM stages and operations and instructs the Application Gateway to perform operations on physical and logical elements?
- A. Cisco Application Gateways
- B. Cisco Data Management Engine
- C. Cisco Finite State Machine
- D. Cisco UCS Manager
Answer: B
Explanation:
Reference:
https://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/ucs-manager/GUI-User-Guides/System-Monitoring/3-1/b_UCSM_GUI_System_Monitoring_Guide_3_1/b_UCSM_GUI_System_Monitoring_Guide_3_1_chapter_0100.html
NEW QUESTION 26
What is the next step after performing a UCS firmware upgrade, and downloading the latest drivers both for your RAID Controller and your Fibre Channel HBA?
Check the HCL
- A. No Drivers are needed in a UCS environment
- B. No need to do anything Drivers are automatically installed for you
- C. Apply the device driver update to the devices
- D. Test device driver compatibility
Answer: D
NEW QUESTION 27
A new UCS dual fabric cluster is being configured with a single chassis. The administrator notices that the cluster is not in High Availability (HA) mode. What is the possible cause?
- A. The HA plugin has not been installed in UCS Manager
- B. The links to the chassis are not enabled
- C. The UCS-FI-HA license has not been activated in UCS Manager
- D. No uplinks are active into the data center.
Answer: A
NEW QUESTION 28
After installing a new UCS M4 server, which two Cisco Integrated Management Controller connectivity options do you have? (Choose two )
- A. In-band Access
- B. Web Access
- C. Out-of-Band Access
- D. XML API Access
- E. SNMP
Answer: A,D
NEW QUESTION 29
When configuring UCS SAN Connectivity to a 3rd Party FibreChannel Storage Array that is connecting directly to the UCS Fabric Interconnects, which option is Cisco recommended'?
- A. Connect the Storage Array to a FC Storage Port and Enable Switching Mode on the UCS Fabric Interconnects
- B. Connect the Storage Array to an Appliance Port and Enable Switching Mode on the UCS Fabric Interconnects
- C. Direct connectivity between UCS Fabric Interconnects and FibreChannel Storage Arrays is not supported
- D. Connect the Storage Array to a RC Storage Port and Enable NPV Mode on the UCS Fabric Interconnects
- E. Connect the Storage Array to an Appliance Port and Enable NPV Mode on the UCS Fabric Interconnects
Answer: A
NEW QUESTION 30
You are in the process of upgrading your UCS M3 Server to a newer UCS M4 Server. You associate the Service Profile to the new UCS Server, but it fails to boot You suspect of a failed boot hard drive. You check your RAID1 Boot LUN in UCS Manager, but see no error messages What could be causing the issue?
- A. The newer Cisco UCS M4 Server is using flash drives, not hard drives
- B. A misconfiguration on the Service Profile Local Disk Policy
- C. The newer Cisco UCS M4 Server is using disks of larger capacity than the previous UCS M3 Server
- D. A misconfiguration on the Service Profile Local Boot Policy
Answer: A
NEW QUESTION 31
Which statement best describes managing Cisco UCS servers using NX-OS CLI on the Fabric Interconnects?
- A. The NX-OS CLI on the Fabric Interconnects allows you to manage QoS parameters on the Fabric Interconnects and an upstream LAN switch
- B. The NX-OS CLI on the Fabric Interconnects allows you to change the connectivity configuration between the servers and Fabric Interconnects
- C. The NX-OS CLI on the Fabric Interconnects allows you to change the connectivity configuration between the Fabric Interconnects and an upstream LAN switch.
- D. The NX-OS CLI on the Fabric Interconnects allows you to view, but not change the connectivity configuration between the Fabric Interconnects and an upstream LAN switch.
Answer: C
NEW QUESTION 32
When booting up a Cisco UCS Server you want to see boot time diagnostic messages of the POST, what action is required for you to do so?
- A. Enable Quiet Boot on the Server's BIOS
- B. Restart the Server
- C. Disable Fast Boot on the Server's Service Profile
- D. Enable Quiet Boot on the Server's Service Profile
- E. Disable Fast Boot on the Server's BIOS
Answer: D
NEW QUESTION 33
A Hard Drive (HDD) has been hot swapped in a UCS server blade, however, the UCS Manager GUI is not displaying updated metrics about the replacement drive. What action will be required to properly display updated metrics?
- A. Reboot the server.
- B. Reboot the Fabric Interconnects
- C. Remove and re-insert the server blade HDD controller mezzanine card
- D. Use the CLI, since HDD metrics cannot be displayed with the UCS Manager GUI
Answer: C
NEW QUESTION 34
If a Cisco UCS B-Series server fails to initialize, which method of access is required to troubleshoot?
- A. Use Cisco UCS Manager GUI to troubleshoot initialization
- B. Use KVM console to troubleshoot initialization
- C. Use direct console access to troubleshoot initialization
- D. Use Cisco UCS Manager API to troubleshoot initialization
Answer: B
NEW QUESTION 35
Which command sequence is required to reset Cisco Integrated Management Controller (IMC) of a Cisco UCS Server?
- A. connect cimc | reset | validate
- B. scope cimc | reset | commit-buffer
- C. connect cimc | reset | commit
- D. scope cimc | reset | validate
Answer: B
NEW QUESTION 36
What is the result of enabling the Core File Exporter in UCS Manager?
- A. If a subsequent triggering event occurs, a core dump will be generated and sent by TFTP
- B. A core dump must be remotely activated by Cisco TAC.
- C. A core dump file will be immediately created and transmitted using HTTP protocol
- D. A core dump will immediately be generated and will be exported
Answer: D
NEW QUESTION 37
Which statement is true regarding the UCS Manager GUI is showing "Overall Status Unassociated" in the General tab for a C-series server?
- A. The server is not properly connected
- B. The server has a service profile assigned, but has connectivity issues with UCS Manager
- C. The server has been properly connected, but has not been discovered by UCS Manager
- D. The server does not have a service profile assigned, but has been discovered by UCS Manager
Answer: A
NEW QUESTION 38
......
500-920 Deluxe Study Guide with Online Test Engine: https://www.actual4cert.com/500-920-real-questions.html