[2024] NS0-516 All-in-One Exam Guide Practice To your NS0-516 Exam! [Q19-Q43]

Share

[2024] NS0-516 All-in-One Exam Guide Practice To your NS0-516 Exam!

Preparations of NS0-516 Exam 2024 NCIE SAN E-Series Unlimited 66 Questions


The NS0-516 exam is intended for IT professionals who have experience working with NetApp E-Series storage systems and are seeking to enhance their skills and knowledge in this area. Candidates should have a strong understanding of SAN architecture and design, as well as experience working with Fibre Channel, iSCSI, and SAS protocols. Additionally, candidates should have experience with SAN management tools and techniques, including zoning, masking, and LUN configuration.


The NS0-516 exam covers a wide range of topics related to NetApp E-Series SAN solutions, including SAN design and implementation, data protection and disaster recovery, performance optimization, and troubleshooting. NS0-516 exam is divided into multiple sections, each of which focuses on a specific area of SAN implementation and management. To pass the exam, candidates must demonstrate their proficiency in each of these areas and show that they have the skills and knowledge required to implement and manage NetApp E-Series SAN solutions.


Network Appliance NS0-516 certification exam is designed for individuals who want to prove their expertise in implementing NetApp E-Series SAN solutions. NS0-516 exam focuses on testing the knowledge and skills required to deploy, manage, and troubleshoot E-Series SAN solutions in a NetApp storage environment. NetApp Implementation Engineer SAN Specialist E-Series (NCIE) certification exam is intended for professionals who have experience in installing, configuring, and maintaining E-Series SAN solutions.

 

NEW QUESTION # 19
A customer intends to use an E2812 system without expansion shelves. The specification for their Windows host requires that six E-Series data volumes be used.
In this scenario, how should the system be configured?

  • A. one DDP for each volume
  • B. two DDPs with the volumes divided equally
  • C. three DDPs with the volumes divided equally
  • D. one DDP with all the volumes

Answer: D

Explanation:
* Understand the Requirements:The E2812 system is to be used without expansion shelves, and the customer requires six data volumes.
* Consider DDP (Dynamic Disk Pooling):DDP is a recommended configuration for simplifying management and enhancing data protection.
* Single DDP Configuration:Using one DDP for all volumes is efficient for the following reasons:
* Simplifies the storage configuration.
* Ensures balanced use of all drives.
* Provides efficient data protection and rebuild performance.
* Creation of Volumes:Within the single DDP, create six volumes as required by the customer.
* Advantages of One DDP:
* Easier management compared to multiple DDPs.
* Better performance and protection due to the distributed nature of DDP.


NEW QUESTION # 20
If an FDE disk fails, which characteristic is required of the replacement disk?

  • A. Must be T10-P1 capable
  • B. Must be loaded with DACstore
  • C. Must be FDE capable
  • D. Must be of a greater capacity

Answer: C


NEW QUESTION # 21
What does the storage system use to preserve cache data in the event of a complete controller failure? (Choose the best answer.)

  • A. Pre-fetch caching
  • B. Write caching
  • C. Read caching
  • D. Cache mirroring
  • E. Flash read cache

Answer: D


NEW QUESTION # 22
What happens if one disk chosen for a volume group has a capacity of 2 TB and the other five disks have a capacity of 4 TB?

  • A. SANtricity allows the creation of the volume group but places it offline until you add another 2-TB disk.
  • B. SANtricity recognizes all disks as 4 TB.
  • C. SANtricity recognizes all disks as 2 TB.
  • D. SANtricity will never allow this combination.

Answer: C


NEW QUESTION # 23
Click the Exhibit button.

Referring to the exhibit, what would you select in the search list to see all of the host selections for NetApp E-Series storage systems?

  • A. E-Series SAN Host
  • B. E-Series Controller Firmware
  • C. Storage OS
  • D. SANtricity

Answer: A

Explanation:
Explanation
Reference
https://www.google.com/url?sa=t&rct=j&q=&esrc=s&source=web&cd=1&ved=2ahUKEwirltOiyqvnAhVhu3EK


NEW QUESTION # 24
Which iSCSI setting would you change from its default value to increase the throughput of an iSCSI host port on a NetApp E-Series system?

  • A. Challenge-Handshake Authentication Protocol (CHAP)
  • B. maximum transmission unit (MTU)
  • C. Time to Live (TTL)
  • D. flow control

Answer: B

Explanation:
To increase the throughput of an iSCSI host port on a NetApp E-Series system, you should change the maximum transmission unit (MTU)setting from its default value.
* Maximum Transmission Unit (MTU):The MTU size determines the largest packet that can be sent over the network without needing to be fragmented. By increasing the MTU size, you can reduce the overhead associated with packet processing and improve throughput. For example, setting the MTU to
9000 bytes (Jumbo Frames) can enhance performance for iSCSI traffic.
References:
* NetApp E-Series SANtricity Storage Manager User Guide
* NetApp Best Practices for Configuring iSCSI with E-Series


NEW QUESTION # 25
You have two Linux hosts that must be connected over multiple paths to two NetApp E-Series systems. One with FC and the other with SAS.
In this scenario, which mutipathing driver should you use for each system to complete this task?

  • A. Use DM-MP for FC and SAS.
  • B. Use LVM for FC and SAS.
  • C. Use DM-MP for FC and LVM for SAS.
  • D. Use DM-MP for SAS and LVM for FC.

Answer: A


NEW QUESTION # 26
Which NetApp tool provides information on size, weight, acoustic noise, and power of NetApp E-Series systems?

  • A. Interoperability Matrix Tool
  • B. Hardware Universe
  • C. Active IC
  • D. Config Advisor

Answer: B


NEW QUESTION # 27
What is the proper order to power-on E-Series arrays when a storage system has at least 2 trays? (Choose the best answer.)

  • A. Power up A-side power supplies first, then power up all B-side power supplies.
  • B. Power on the controller drive tray first, then wait several minutes for the controller drive tray to spin up, and then power on all expansion drive trays
  • C. Power all expansion drive trays first, wait several minutes for the expansion drive trays to spin up, and then power on the controller drive tray
  • D. Power on in any order, since the order does not matter

Answer: B


NEW QUESTION # 28
Which two errors would fail a pre-upgrade health check? (Choose two.)

  • A. Volumes are reported on a non-preferred path
  • B. I/O is being processed
  • C. An excess number of event log events are present
  • D. Hot spares are in use

Answer: A,B

Explanation:
* Understand Pre-Upgrade Health Check:
* Purpose:The pre-upgrade health check is designed to ensure the system is in a stable state before proceeding with firmware or software upgrades. This helps to avoid disruptions and data loss.
* Volumes on Non-Preferred Path (B):
* Issue:If volumes are reported on a non-preferred path, it indicates that there might be a pathing issue or an imbalance in the I/O load.
* Impact:Non-preferred paths can lead to performance degradation and increased latency, which might cause issues during the upgrade process.
* Resolution:Ensure that all volumes are accessible through their preferred paths before initiating the upgrade.


NEW QUESTION # 29
Which NetApp tool provides information on size, weight, acoustic noise, and power of NetApp E-Series systems?

  • A. Interoperability Matrix Tool
  • B. Active IQ
  • C. Hardware Universe
  • D. Config Advisor

Answer: C

Explanation:
* Explanation:
* The Hardware Universe is a NetApp tool that provides comprehensive information on the size, weight, acoustic noise, and power requirements of NetApp systems, including the E-Series.
* This tool is essential for planning and managing the physical aspects of deploying NetApp hardware in a data center environment.


NEW QUESTION # 30
Multipath drivers provide which high-level features?

  • A. They identify a failed disk and its path.
  • B. They check the state of known and discovered paths and monitor host connections.
  • C. They specify the rate of data transfer and reroute host requests.
  • D. They present volumes as LUNs to the hosts and allow you to take them offline.

Answer: B


NEW QUESTION # 31
What does the CHAP secret accomplish for an E-Series system?

  • A. FC authentication
  • B. SAS authentication
  • C. Ethernet management authentication
  • D. iSCSI authentication

Answer: D

Explanation:
* CHAP (Challenge Handshake Authentication Protocol): CHAP is a protocol used to authenticate the identity of an initiator or target in iSCSI communications. This ensures that only authorized devices can connect to the storage array over the iSCSI network.
* Implementation in E-Series: In the context of E-Series systems, CHAP secrets are configured to provide an additional layer of security by requiring both the initiator and target to authenticate each other using a shared secret before establishing an iSCSI session.
References:
* NetApp E-Series SANtricity System Manager documentation on iSCSI setup
* NetApp Implementation Engineer - SAN Specialist - E-Series manuals


NEW QUESTION # 32
You are cabling drive expansion shelves for an E2800 storage system.
In this scenario, which cabling method should you use?

  • A. You use SAS expansion port EXP1 and reserve SAS expansion port EXP2 for a second drive expansion stack.
  • B. The controller A and the controller B SAS expansion ports (EXP1 & EXP2) should be divided between the A-side and B-side IOM-12 modules for all the expansion shelves.
  • C. The controller A and the controller B SAS expansion ports (EXP1 & EXP2) should not be divided between the A-side and B-side IOM-12 modules for all of the expansion shelves.
  • D. You use SAS expansion port EXP2 and reserve SAS expansion port EXP1 for a second drive expansion stack.

Answer: B

Explanation:
Explanation
Reference https://library.netapp.com/ecm/ecm_download_file/ECMLP2773537


NEW QUESTION # 33
Which two steps are required to enable multifactor authentication on an E-Series system? (Choose two)

  • A. Test SSO login
  • B. Configure LDAP
  • C. Configure In-Band Management
  • D. Map roles

Answer: B,D


NEW QUESTION # 34
Which two steps are required to enable multifactor authentication on an E-Series system? (Choose two.)

  • A. Configure LDAP
  • B. Test SSO login
  • C. Map roles
  • D. Configure In-Band Management

Answer: A,B


NEW QUESTION # 35
Exhibit:

Referring to the exhibit, what would you select in the search list to see all of the host selections for NetApp ESeries storage systems?

  • A. E-Series SAN Host
  • B. E-Series Controller Firmware
  • C. Storage OS
  • D. SANtricity

Answer: A


NEW QUESTION # 36
What is represented by the Headroom graph on the SANtricity System Manager performance tab?

  • A. the percentage of CPU processing capacity that is being used by the operations on the system
  • B. the percentage of I/O associated with the backend disk drives
  • C. the resources that are being consumed by a defined workload
  • D. the remaining performance capability of the physical objects in the storage system

Answer: D


NEW QUESTION # 37
Consult the ___________ to determine the current link status of a host port. (Choose the best answer.)

  • A. Real-time performance monitor
  • B. Unreadable Sectorslog
  • C. Recovery Guru
  • D. Storage Array Profile

Answer: D


NEW QUESTION # 38
A company is using the Federal Information Processing Standard (FIPS) on all volume groups. However, one volume group failed a security audit.
In this scenario what would cause a volume group to fail the security audit?

  • A. Connectivity to the key server was interrupted
  • B. Data Assurance was changed to "disabled" for the volume group
  • C. An FDE drive was added as a spare in the volume group
  • D. The Secure Erase operation was applied to the volume group disks

Answer: C


NEW QUESTION # 39
Which command on a NetApp storage controller will display the average latency time on a per LUN basis every five seconds?

  • A. fcp stats -i 5
  • B. sysstat -f 5
  • C. sysstat -i 5
  • D. lun stats -i 5

Answer: D

Explanation:
Purpose: To display the average latency time on a per LUN basis.
Command:lun stats -i 5
* Usage: Provides performance statistics, including latency, for each LUN at specified intervals (every 5 seconds in this case).
References: NetApp Data ONTAP Command Reference Guide.


NEW QUESTION # 40
Which data protection strategy has the most overhead capacity as a percentage of the total capacity?

  • A. RAID 6
  • B. Dynamic Disk Pools (DDP)
  • C. RAID 5
  • D. RAID 10

Answer: D

Explanation:
* RAID Levels Overview:
* RAID 5: Single parity, moderate overhead.
* RAID 6: Dual parity, higher overhead than RAID 5.
* RAID 10: Mirroring and striping, highest overhead due to 100% redundancy (mirroring).
* Dynamic Disk Pools (DDP): Efficient use of capacity but more overhead than RAID 5.
* Overhead Calculation:
* RAID 10 has the most overhead because it mirrors all data, effectively using twice the storage capacity.
* Capacity Overhead: The overhead in RAID 10 is 50% of the total capacity, meaning if you have 1 TB of usable storage, you need 2 TB of total storage.
References: NetApp E-Series Storage Management Guide, RAID level comparison charts.


NEW QUESTION # 41
Click the Exhibit button.

A customer has a raised floor with a weight limit of 700 lb. per floor tile. The customer's data cabinet weights
90 lb. and covers a single floor tile.
Referring to the exhibit, what is the maximum number of E2824 shelves possible to be installed?

  • A. 0
  • B. 1
  • C. 2
  • D. 3

Answer: D

Explanation:
* Total weight capacity per tile: 700 lb.
* Data cabinet weight: 90 lb.
* Available weight for shelves: 700 lb. - 90 lb. = 610 lb.
* Weight of an E2824 shelf (maximum): 60.5 lb.
* Number of shelves: 610 lb. / 60.5 lb. 10 shelves
* However, considering the safety margin and not exceeding the weight limit, we take 6 shelves as a practical maximum.
* References: Weight table for E2824 controller shelf and EF280 flash array.


NEW QUESTION # 42
Which three factors should you consider before you install an E2860 in a data center? (Choose three)

  • A. current draw
  • B. ambient temperatures
  • C. heat dissipation
  • D. fire suppression capacity
  • E. electromagnetic interference

Answer: A,B,C


NEW QUESTION # 43
......

Focus on NS0-516 All-in-One Exam Guide For Quick Preparation: https://www.actual4cert.com/NS0-516-real-questions.html

Practice To NS0-516 - Actual4Cert Remarkable Practice On your NetApp Implementation Engineer SAN Specialist E-Series (NCIE) Exam: https://drive.google.com/open?id=1scISAkkTeo4EpcOHGlmpRlOLlkJCC_IS